<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-07 02-27-08
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 43 dBuV EVROPA 2
Pilot RDS Phase Difference
6.6 kHz 2.6 kHz 44 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 51 kHz 19097 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,1 dBr -0,51 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"EVROPA 2" 2204 10 (Pop M) 1 0 1 1 2:27, 7.04.2026
RT
"LEWIS CAPALDI - Survive "
AF EON
92.9, 94.6, 99.3, 99.5, 99.7, 101.5, 105.1, 105.5, 106.7 MHz -
FM Scope Max at: 51 kHz MIN: 9 kHz % above 77 kHz: 0,0000 Acquired: 2026/04/07 2:27:05 Total samples: 19097 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,1 dBr MIN: -1,1 dBr AVE: -0,51 dBr % above 0,2 dBr: 0,0 Last value: -0,1 dBr (2026/04/07 2:27:05) 02:14 02:16 02:18 02:20 02:22 02:24 02:26 0 50 100 Dev. MAX [kHz] -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality